Zamdon 1.5Kw Solar Inverter (Single Phase)

• Solar Inverter (Single Phase)

• DP-15212;

• 1.5KW/12VDC;

• 1500Watts Output

• AC output voltage: 240V/50Hz;

• Toroidal transformer lower loss;

• Pure sine wave AVR output;

• Transfer time ≤4ms;

• LCD display, wall-mounted design;

• RS485 communication port;

• (Exclude Inbuilt charge control)

• 24 months Warranty

• Countrywide Delivery

◆  Low frequency toroidal transformer increase efficiency,Pure sine wave output;

◇  Integrated LCD display; One-button start with an external display screen( optional);

◆  Dedicated DCP chip design; stable and high-speed operation;

◇  LCD display, easy to monitor the operation condition in real time;

◆  AC charge current 0-30A adjustable; battery capacity configuration more flexible;

◇ Three types working modes adjustable:AC first, DC first, energy-saving mode;

◆ AVR output, all-around automatic protection function;

◆  Built-in PWM or MPPT controller optional;

◇  Added fault codes query function,facilitate user to monitor the operation state in real time;

◆ Supports diesel or gasoline generator, adapt any tough electricity situation;

◇  RS485  communication port/APP optional. 

 

Parameters Table:

Specification
Model: DP/DP-T10212/24/4815212/24/4820212/24/4830224/4840224/48502486024870248
Rated Power1000W1500W2000W3000W4000W5000W6000W7000W
Peak Power(20ms)3000VA4500VA6000VA9000VA12000VA15000VA18000VA21000VA
Start Motor1HP1.5HP2HP3HP3HP4HP4HP5HP
Battery Voltage12/24/48VDC24/48VDC24/48VDC48VDC
Size(L*W*Hmm)555*297*184615*315*209
Packing Size(L*W*Hmm)620*345*255680*365*280
N.W.(kg)121315.5182324.52627.5
G.W.(kg)(Carton Packing)141517.52025.52728.530
Installation MethodWall-Mounted
Parameter
InputDC Input Voltage Range10.5-15VDC(Single battery voltage)
AC Input Voltage Range85VAC~138VAC(110VAC)/ 95VAC~148VAC(120VAC / 170VAC~275VAC(220VAC / 180VAC~285VAC(230VAC)
/ 190VAC~295VAC(240VAC)
AC Input Frequency Range45Hz~55Hz(50Hz) / 55Hz~65Hz(60Hz)
Max AC charging current0~30A(Depending on the model)
AC charging methodThree-stage (constant current, constant voltage, floating charge)
OutputEfficiency(Battery Mode)≥85%
Output Voltage(Battery Mode)110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2%   
Output Frequency(Battery Mode)50/60Hz±1%
Output Wave(Battery Mode)Pure Sine Wave
Efficiency(AC Mode)>99%
Output Voltage(AC Mode)110VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10%   
Output Frequency(AC Mode)Follow input
Output waveform distortion
(Battery Mode)
≤3%(Linear load)
No load loss(Battery Mode)≤0.8% rated power
No load loss(AC Mode) ≤2% rated power( charger does not work in AC mode)
No load loss(Energy saving Mode)≤10W
Battery TypeVRLA BatteryCharge Voltage :14V; Float Voltage:13.8V( 12V system; 24V system x2 ; 48V system x4)
Customize batteryCharging and discharging parameters of different types of batteries can be customized according to user requirements
 (charging and discharging parameters of different types of batteries can be set through the operation panel)
ProtectionBattery undervoltage alarmFactory default: 11V(12V system; 24V system x2; 48V system x4)
Battery undervoltage protectionFactory default: 10.5V(12V system; 24V system x2; 48V system x4)
Battery overvoltage alarmFactory default: 15V(12V system; 24V system x2; 48V system x4)
Battery overvoltage protectionFactory default:  17V(12V system; 24V system x2; 48V system x4)
Battery overvoltage recovery voltageFactory default:  14.5V(12V system; 24V system x2; 48V system x4)
Overload power protectionAutomatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protectionAutomatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection>90°C(Shut down output)
AlarmANormal working condition, buzzer has no alarm sound
BBuzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
CWhen the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Inside Solar controller
(Optional)
Charging ModePWM or MPPT
Charging current10A~60A(PWM or MPPT)10A~60A(PWM )  / 10A~100A(MPPT)
PV Input Voltage RangePWM: 15V-44V(12V system); 30V-44V(24V system); 60V-88V(48V system)
MPPT: 15V-120V(12V system); 30V-120V(24V system); 60V-120V(48V system)
Max PV Input Voltage(Voc)
(At the lowest temperature)
PWM: 50V(12V/24V system); 100V(48V system) / MPPT: 150V(12V/24V/48V system)
PV Array Maximum Power12V system: 140W(10A)/280W(20A)/420W(30A)/560W(40A)/700W(50A)/840W(60A)/1120W(80A)/1400W(100A);
24V system: 280W(10A)/560W(20A)/840W(30A)/1120W(40A)/1400W(50A)/1680W(60A)/2240W(80A)/2800W(100A);
48V system: 560W(10A)/1120W(20A)/1680W(30A)/2240W(40A)/2800W(50A)/3360W(60A)/4480W(80A)/5600W(100A)
Standby loss≤3W
Maximum conversion efficiency>95%
Working ModeBattery First/AC First/Saving Energy Mode
Transfer Time≤4ms
DisplayLCD(External LCD Display(Optional))
Thermal methodCooling fan in intelligent control
Communication(Optional)RS485/APP(WIFI monitoring or GPRS monitoring)
EnvironmentOperating temperature-10℃~40℃
Storage temperature-15℃~60℃
Noise≤55dB
Elevation2000m(More than derating)
Humidity0%~95% ,No condensation
Note: All specifications are subject to charge without prior notice



Call/WhatsApp with us Via +254 790 108845 | +254 703 163326

Did you know you can Visit us today at: Shop F3, 1st Flr. Barkat Biashara Mall. Opp Simba Coach Booking. River Road- Kumasi Junction?

There have been no reviews for this product yet.

Product Queries (0)

Login or Registerto submit your questions to seller

Other Questions