PV3000 VHM series is very economical pure sine wave solar inverter, Inbuilt with 80A MPPT charger; Solar/AC priority is configurable, when setting solar priority, solar will charge batteries as first priority, and AC can also charge batteries when solar charger current is too lower, in this way system charge is optimazed best. it enables inverter to operate with all kinds of home appliances.
• Pure sine wave output
Specification:
MODEL | PV30-1KW VHM | PV30-1.5KW VHM | PV30-2KW VHM | PV30-3KW VHM | ||||
---|---|---|---|---|---|---|---|---|
Nominal Battery System Voltage | 12VDC | 24VDC | 12VDC | 24VDC | 12VDC | 24VDC | 24VDC | 48VDC |
INVERTER OUTPUT | ||||||||
Rated Power | 1 KW | 1.5 KW | 2 KW | 3 KW | ||||
Surge Rating | 3000VA | 4500VA | 6000VA | 9000VA | ||||
Capable Of Starting Electric Motor | 1HP | 1HP | 1HP | 2HP | ||||
Waveform | Pure sine wave / same as input (bypass mode) | |||||||
Nominal Output Voltage RMS | 220V / 230V / 240VAC (±10% RMS) | |||||||
Output Frequency | 50Hz / 60Hz ±0.3Hz | |||||||
Inverter Efficiency (Peak) | >88% | |||||||
Line Mode Efficiency | >95% | |||||||
Power Factor | 1.0 | |||||||
Typical Transfer Time | 10ms(max) | |||||||
AC INPUT | ||||||||
Voltage | 230VAC | |||||||
Selectable Voltage Range | 150~265VAC(For personal computers) | |||||||
Frequency Range | 50Hz / 60Hz(Auto sensing) 40~80Hz | |||||||
BATTERY | ||||||||
Minimum Start Voltage | (10V / 10.5V / 11V / 11.5V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||
Low Battery Alarm | (10V / 10.5V / 11V / 11.5V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||
Low Battery Cut Off | 10V / 10.5V / 11V / 11.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||
High Voltage Alarm | (13.8-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||
High Battery Voltage Recover | (13.8-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||
Idie Consumption-Search Mode | Load ≤50±20W(120V)/100±20W(220V) | |||||||
CHARGER | ||||||||
Output Voltage | Depends on battery type | |||||||
Overcharge Protection S.D. | 15.7VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode) | |||||||
Maximum Charge Current | 30A | 20A | 45A | 25A | 60A | 30A | 40A | 20A |
BYPASS & PROTECTION | ||||||||
Input Voltage Waveform | Sine wave (grid or generator) | |||||||
Nominal Input Frequency | 50Hz or 60Hz | |||||||
Overload Protection (SMPS Load) | Circuit breaker | |||||||
Output Short Circuit Protection | Circuit breaker | |||||||
AC Input Breaker | 1-3K/30A | |||||||
SOLAR CHARGER | ||||||||
Maximum PV Array Power | 1250W | 2500W | 1250W | 2500W | 1250W | 2500W | 2500W | 5000W |
Maximum PV Charge Current | 80A±4A | |||||||
DC Voltage | 12V / 24V auto work | |||||||
MPPT Range @ Operating Voltage | 16~100VDC @ 12V/32~145VDC @ 24V | |||||||
Maximum PV Array Open Circuit Voltage | 145VDC | |||||||
Standby Power Consumption | <2W | |||||||
MECHANICAL SPECIFICATIONS | ||||||||
Mounting | Wall Mount | |||||||
Dimensions (W*H*D) | 302.8*460*199.8mm | |||||||
Net Weight (Solar CHG)(kg) | 17.2 | 17.7 | 21.8 | 20.7 | 25.2 | 25.5 | ||
Shipping Dimensions (W*H*D) | 400*319*615mm | |||||||
Shipping Weight (Solar CHG)(kg) | 20 | 20.7 | 24.8 | 23.5 | 28.2 | 28.2 | ||
OTHER | ||||||||
Operation Temperature Range | 0℃ to 40℃ | |||||||
Storage Temperature | -15℃ to 60℃ | |||||||
Audible Noise | 60dB MAX | |||||||
Display | LED+LCD |
MODEL | PV30-4KW VHM | PV30-5KW VHM | PV30-6KW VHM | |
---|---|---|---|---|
Nominal Battery System Voltage | 24VDC | 48VDC | 48VDC | 48VDC |
INVERTER OUTPUT | ||||
Rated Power | 4 KW | 5 KW | 6 KW | |
Surge Rating | 12000VA | 15000VA | 18000VA | |
Capable Of Starting Electric Motor | 2HP | 3HP | ||
Waveform | Pure sine wave / same as input (bypass mode) | |||
Nominal Output Voltage RMS | 220V / 230V / 240VAC (±10% RMS) | |||
Output Frequency | 50Hz / 60Hz ±0.3Hz | |||
Inverter Efficiency (Peak) | >88% | |||
Line Mode Efficiency | >95% | |||
Power Factor | 1.0 | |||
Typical Transfer Time | 10ms(max) | |||
AC INPUT | ||||
Voltage | 230VAC | |||
Selectable Voltage Range | 150~265VAC(For personal computers) | |||
Frequency Range | 50Hz / 60Hz(Auto sensing) 40~80Hz | |||
BATTERY | ||||
Minimum Start Voltage | (10V / 10.5V / 11V / 11.5V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||
Low Battery Alarm | (10V / 10.5V / 11V / 11.5V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||
Low Battery Cut Off | 10V / 10.5V / 11V / 11.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||
High Voltage Alarm | (13.8-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||
High Battery Voltage Recover | (13.8-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||
Idie Consumption-Search Mode | Load ≤50±20W(120V)/100±20W(220V) | |||
CHARGER | ||||
Output Voltage | Depends on battery type | |||
Overcharge Protection S.D. | 15.7VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode) | |||
Maximum Charge Current | 60A | 30A | 35A | 40A |
BYPASS & PROTECTION | ||||
Input Voltage Waveform | Sine wave (grid or generator) | |||
Nominal Input Frequency | 50Hz or 60Hz | |||
Overload Protection (SMPS Load) | Circuit breaker | |||
Output Short Circuit Protection | Circuit breaker | |||
AC Input Breaker | 4-6K/50A | |||
SOLAR CHARGER | ||||
Maximum PV Array Power | 2500W | 5000W | 5000W | 5000W |
Maximum PV Charge Current | 80A±4A | |||
DC Voltage | 24V / 48V auto work | |||
MPPT Range @ Operating Voltage | 32~145VDC @ 24V/64~145VDC @ 48V | |||
Maximum PV Array Open Circuit Voltage | 145VDC | |||
Standby Power Consumption | <2W | |||
MECHANICAL SPECIFICATIONS | ||||
Mounting | Wall Mount | |||
Dimensions (W*H*D) | 305.4*531*200.3mm | |||
Net Weight (Solar CHG)(kg) | 38.9 | 36.5 | 45.7 | 45.7 |
Shipping Dimensions (W*H*D) | 400*317*686mm | |||
Shipping Weight (Solar CHG)(kg) | 43 | 40.7 | 50 | 50 |
OTHER | ||||
Operation Temperature Range | 0℃ to 40℃ | |||
Storage Temperature | -15℃ to 60℃ | |||
Audible Noise | 60dB MAX | |||
Display | LED+LCD |