Discover the essential guide to Felicity Inverters Fault Codes, brought to you by Kreatives.co.ke. When a fault occurs, your inverter will cut off output, the fault LED will turn on, and the fault code along with "ERROR" will be displayed on the LCD screen. This table helps you identify issues and apply the right troubleshooting steps to keep your system running smoothly.
Fault Code | Fault Information | Troubleshooting |
---|---|---|
01 | Bus voltage is too high | AC surge or internal components failed. Restart the unit; if error persists, return to repair center. |
02 | Bus voltage is too low | Internal components failed. Restart the unit; if error persists, return to repair center. |
03 | Bus soft start fail | Internal components failed. Restart the unit; if error persists, return to repair center. |
04 | Inverter soft start fail | Internal components failed. Restart the unit; if error persists, return to repair center. |
05 | Over current or surge detected by software | Restart the unit; if error persists, return to repair center. |
06 | Over current or surge detected by hardware | Restart the unit; if error persists, return to repair center. |
07 | Output voltage is too low | Reduce the connected load. Restart the unit; if error persists, return to repair center. |
08 | Output voltage is too high | Restart the unit; if error persists, return to repair center. |
09 | Output short circuited | Check if wiring is connected well and remove abnormal load. |
10 | Overload time out | Reduce the connected load by switching off some equipment. |
11 | Battery voltage is too high | Check if spec and quantity of batteries meet requirements. |
12 | Over current happen at DCDC circuit | Restart the unit; if error persists, return to repair center. |
13 | PV voltage is too high | Reduce the number of PV modules in series. |
14 | Short circuited happen at PV port | Check if wiring is connected well. |
15 | PV power is abnormal | Reduce the number of PV modules. |
16 | Over current happen at PV port | Restart the unit; if error persists, return to repair center. |
17 | Fan is locked | Check if wiring is connected well. Replace the fan. |
18 | Over temperature happen at PV circuit | Check if air flow is blocked or ambient temperature is too high. |
19 | Over temperature happen at battery circuit | Check if air flow is blocked or ambient temperature is too high. |
20 | Over temperature happen at inverter circuit | Check if air flow is blocked or ambient temperature is too high. |
21 | The inner temperature over | Check if air flow is blocked or ambient temperature is too high. |
22 | DCDC current sensor failed | Restart the unit; if error persists, return to repair center. |
23 | No.2 DCDC current sensor failed | Restart the unit; if error persists, return to repair center. |
24 | Inverter current sensor failed | Restart the unit; if error persists, return to repair center. |
25 | OP current sensor failed | Restart the unit; if error persists, return to repair center. |
26 | Sharing current sensor failed | Restart the unit; if error persists, return to repair center. |
27 | AC input and output wires are inversely connected | Check AC input/output wires; for parallel installation, ensure correct wiring and restart inverters. |
28 | Single unit is installed to parallel system | Check wiring connection; for parallel installation, ensure correct connection and restart inverters. |
29 | DC/DC soft start fail | Restart the unit; if error persists, return to repair center. |
30 | CAN data loss | Check communication cables and restart the inverter. |
31 | Host data loss | Check communication cables and restart the inverter. |
32 | Synchronization data loss | Restart the inverter. |
33 | Current feedback into the inverter is detected | Check if L/N cables are connected reversely; ensure proper sharing cables and phase system. |
34 | The firmware version is not the same | Update all inverter firmware to the same version; check LCD setting and CPU firmware. |
35 | The output current of each inverter is different | Check sharing cables and restart the inverter. |
36 | AC output mode setting is different | Switch off inverter, check LCD setting (program 28), ensure consistent three-phase settings. |
Spot the Code: Note the fault code on your Felicity Inverter’s LCD when the fault LED is on.
Apply Fixes: Follow the troubleshooting steps for each code.
Seek Support: For unresolved issues, contact your installer or Kreatives.co.ke support.
Felicity Inverters offer reliable power solutions with clear fault diagnostics. Available with countrywide delivery, explore our range at Kreatives.co.ke today!