Must 5Kva 48V 80A 145VDC Solar Hybrid Inverter Charger Low Frequency - PV30-5048VHM

(0 reviews)
Estimate Shipping Time: 1 Days

Sold by:
Inhouse product

Price:
Ksh81,000.00 /Unit
Discount Price:
Ksh78,000.00 /Unit

Quantity:
(100 available)

Total Price:
Share:

Must 5Kva 48V 80A 145VDC Solar Hybrid Inverter Charger Low Frequency - PV30-5048VHM

Low Frequency Off Grid Solar Inverter

PV3000 VHM series is very economical pure sine wave solar inverter, Inbuilt with 80A MPPT charger; Solar/AC priority is configurable, when setting solar priority, solar will charge batteries as first priority, and AC can also charge batteries when solar charger current is too lower, in this way system charge is optimazed best. it enables inverter to operate with all kinds of home appliances.

• Pure sine wave output

  • • 3 Steps charging
  • • Overload and short-circuit protection
  • • Set charging voltage/charging current
  • • Battery low voltage shutdown point can be set to 10/10.5/11V/11.5V
  • • Power-save mode
  • • Set utility priority /battery priority
  • • Set utility input wide/narrow voltage range
  • • Inverter voltage can be set to 220V/230V/240V
  • • Inverter frequency can be set to 50Hz/60Hz
  • • Set utility charging on/off switch
  • • Inbuilt 80A MPPT Solar Charge Controller
  • • Acid or Lithium Select
  • • WiFi port

Specification:

MODELPV30-1KW VHMPV30-1.5KW VHMPV30-2KW VHMPV30-3KW VHM
Nominal Battery System Voltage12VDC24VDC12VDC24VDC12VDC24VDC24VDC48VDC
INVERTER OUTPUT
Rated Power1 KW1.5 KW2 KW3 KW
Surge Rating3000VA4500VA6000VA9000VA
Capable Of Starting Electric Motor1HP1HP1HP2HP
WaveformPure sine wave / same as input (bypass mode)
Nominal Output Voltage RMS220V / 230V / 240VAC (±10% RMS)
Output Frequency50Hz / 60Hz ±0.3Hz
Inverter Efficiency (Peak)>88%
Line Mode Efficiency>95%
Power Factor1.0
Typical Transfer Time10ms(max)
AC INPUT
Voltage230VAC
Selectable Voltage Range150~265VAC(For personal computers)
Frequency Range50Hz / 60Hz(Auto sensing) 40~80Hz
BATTERY
Minimum Start Voltage(10V / 10.5V / 11V / 11.5V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Alarm(10V / 10.5V / 11V / 11.5V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Cut Off10V / 10.5V / 11V / 11.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Voltage Alarm(13.8-14.5V)+1V for 12VDC mode  (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Recover(13.8-14.5V)+0.5V  for 12VDC mode  (*2 for 24VDC, *4 for 48VDC)
Idie Consumption-Search ModeLoad ≤50±20W(120V)/100±20W(220V)
CHARGER
Output VoltageDepends on battery type
Overcharge Protection S.D.15.7VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode)
Maximum Charge Current30A20A45A25A60A30A40A20A
BYPASS & PROTECTION
Input Voltage WaveformSine wave (grid or generator)
Nominal Input Frequency50Hz or 60Hz
Overload Protection (SMPS Load)Circuit breaker
Output Short Circuit ProtectionCircuit breaker
AC Input Breaker1-3K/30A
SOLAR CHARGER
Maximum PV Array Power1250W2500W1250W2500W1250W2500W2500W5000W
Maximum PV Charge Current80A±4A
DC Voltage12V / 24V auto work
MPPT Range @ Operating Voltage16~100VDC @ 12V/32~145VDC @ 24V
Maximum PV Array Open Circuit Voltage145VDC
Standby Power Consumption<2W
MECHANICAL SPECIFICATIONS
MountingWall Mount
Dimensions (W*H*D)302.8*460*199.8mm
Net Weight (Solar CHG)(kg)17.217.721.820.725.225.5
Shipping Dimensions (W*H*D)400*319*615mm
Shipping Weight (Solar CHG)(kg)2020.724.823.528.228.2
OTHER
Operation Temperature Range0℃ to 40℃
Storage Temperature-15℃ to 60℃
Audible Noise60dB MAX
DisplayLED+LCD
MODELPV30-4KW VHMPV30-5KW VHMPV30-6KW VHM
Nominal Battery System Voltage24VDC48VDC48VDC48VDC
INVERTER OUTPUT
Rated Power4 KW5 KW6 KW
Surge Rating12000VA15000VA18000VA
Capable Of Starting Electric Motor2HP3HP
WaveformPure sine wave / same as input (bypass mode)
Nominal Output Voltage RMS220V / 230V / 240VAC (±10% RMS)
Output Frequency50Hz / 60Hz ±0.3Hz
Inverter Efficiency (Peak)>88%
Line Mode Efficiency>95%
Power Factor1.0
Typical Transfer Time10ms(max)
AC INPUT
Voltage230VAC
Selectable Voltage Range150~265VAC(For personal computers)
Frequency Range50Hz / 60Hz(Auto sensing) 40~80Hz
BATTERY
Minimum Start Voltage(10V / 10.5V / 11V / 11.5V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Alarm(10V / 10.5V / 11V / 11.5V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Cut Off10V / 10.5V / 11V / 11.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Voltage Alarm(13.8-14.5V)+1V for 12VDC mode  (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Recover(13.8-14.5V)+0.5V  for 12VDC mode  (*2 for 24VDC, *4 for 48VDC)
Idie Consumption-Search ModeLoad ≤50±20W(120V)/100±20W(220V)
CHARGER
Output VoltageDepends on battery type
Overcharge Protection S.D.15.7VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode)
Maximum Charge Current60A30A35A40A
BYPASS & PROTECTION
Input Voltage WaveformSine wave (grid or generator)
Nominal Input Frequency50Hz or 60Hz
Overload Protection (SMPS Load)Circuit breaker
Output Short Circuit ProtectionCircuit breaker
AC Input Breaker4-6K/50A
SOLAR CHARGER
Maximum PV Array Power2500W5000W5000W5000W
Maximum PV Charge Current80A±4A
DC Voltage24V / 48V auto work
MPPT Range @ Operating Voltage32~145VDC @ 24V/64~145VDC @ 48V
Maximum PV Array Open Circuit Voltage145VDC
Standby Power Consumption<2W
MECHANICAL SPECIFICATIONS
MountingWall Mount
Dimensions (W*H*D)305.4*531*200.3mm
Net Weight (Solar CHG)(kg)38.936.545.745.7
Shipping Dimensions (W*H*D)400*317*686mm
Shipping Weight (Solar CHG)(kg)4340.75050
OTHER
Operation Temperature Range0℃ to 40℃
Storage Temperature-15℃ to 60℃
Audible Noise60dB MAX
DisplayLED+LCD
There have been no reviews for this product yet.

Product Queries (0)

Login or Registerto submit your questions to seller

Other Questions