PV3500 TLV series is a multi-function inverter ,combining functions of inverter and MPPT solar charger controller, solar charger and battery chargerto offer uninterruptible power support. The comprehensive LCD display offers user-configurable and easy-accessible button operation such as batterycharging current, AC/solar charger priority, and selectable input voltage based on different applications.
Features:
• Smart LCD setting(Working modes, Charge Current, Charge voltage, etc.)
• Built-in MPPT solar charge controller 100A
• MPPT efficiency max 98%
• Powerful charge rate up to 80Amp
• DC start &Automatic Self-Diagnostic Function
• USB monitoring function
• Supporting AGS, BTS port
• Compatible to generator
• Countrywide delivery
• 18Months warranty
Call/WhatsApp with us Via +254 790 108845 | +254 703 163326
Nominal Battery System Voltage | 48VDC | ||
INVERTER OUTPUT | |||
---|---|---|---|
Rated power | 8.0KW | 10.0KW | 12.0KW |
Surge rating | 24000VA | 30000VA | 36000VA |
Capable of starting electric motor | 4HP | 5HP | 6HP |
Waveform | Pure sine wave / same as input (bypass mode) | ||
Nominal output voltage RMS | 100V/110V/120V/200V/220V/240V | ||
Output frequency | 50Hz / 60Hz ± 0.3Hz | ||
Inverter effciency(peak) | >88% | ||
Line mode efficiency | >95% | ||
Power factor | 1.0 | ||
Typical transfer time | 20ms(max) | ||
AC INPUT | |||
Voltage | 220V/230V/240V | ||
Selectable voltage range | 90-280 VAC (APL) | ||
Frequency range | 50Hz / 60Hz | ||
BATTERY | |||
Low battery voltage cutoff | 40-48VDC for 48VDC mode | ||
Low battery voltage recover | 42-50VDC for 48VDC mode | ||
High battery voltage cutoff | 60VDC for 48VDC mode | ||
High battery voltage recover | 57VDC for 48VDC mode | ||
Idle consumption-search mode | < 60W when power saver on | ||
AC CHARGER | |||
Output voltage | Depends on battery type | ||
Charger AC input breaker rating | 80A | 80A | 80A |
Overcharge protection S.D. | 31.4VDC for 24VDC mode (62.8VDC for 48VDC mode ) | ||
Maximum charge current | 60A | 70A | 80A |
BTS | |||
Continuous output power | Yes Variances in charging voltage & S.D. voltage base on the battery temperature | ||
BYPASS & PROTECTION | |||
Input voltage waveform | Sine wave (grid or generator) | ||
Nominal input frequency | 50Hz or 60Hz | ||
Overload protection (SMPS Load) | Circuit breaker | ||
Output short circuit protection | Circuit breaker | ||
Bypass breaker rating | 63A | 63A | 63A |
Max bypass current | 80Amp | ||
SOLAR CHARGER | |||
Maximum PV charge current | 100A | ||
DC voltage | 48V | ||
Maximim PV array power | 5000W(10000W for 200A optional) | ||
MPPT range @ operating voltage(VDC) | 64~145VDC | ||
Maximum PV array open circuit voltage | 145VDC | ||
Maximum effciency | >98% | ||
Standby power consumption | <2W | ||
MECHANICAL SPECIFICATIONS | |||
Mounting | Wall mount | ||
Dimensions (W*H*D) | 670*410*215mm | ||
Net weight (solar CHG) (kg) | 69+2.5 | 75.75+2.5 | 75.75+2.5 |
Shipping dimensions (W*H*D) | 884*618*443mm | ||
Shipping weight (Solar CHG) (kg) | 82.5+2.5 | 89+2.5 | 92+2.5 |
OTHER | |||
Operation temperature range | 0°C to 40°C | ||
Storage temperature | -15°C to 60°C | ||
Audible noise | 60dB MAX | ||
Display | LED+LCD | ||
Loading (20GP/40GP/40HQ) | 140pcs / 280pcs / 320pcs |