| Model | FL-SCCM4524 | FL-SCCM6048 | FL-SCCM8048 | FL-SCCM10048 | FL-SCCM12048 |
| Max PV Input Vol | 145V | 195V | |||
| System Vol | 12V/24V/48/(Auto dection) | ||||
| Max battery Charge Current | 45A | 60A | 80A | 100A | 120A |
| PV Array MPPT Vol Range | 15V-130VDC/ 30-130VDC/ 60-130V | 15V-170V/ 30-170V/ 60-170V | |||
| Max PV Input Power(12V) | 625W | 825W | 1100W | 1375W | 1650W |
| Max PV Input Power(24V) | 1250W | 1650W | 2200W | 2750W | 3300W |
| Max PV Input Power(48V) | 2500W | 3300W | 4400W | 5500W | 6600W |
| Charge information | |||||
| Charging Curve | See image below this sheet | ||||
| Charge Algorithm | 3-Step | ||||
| Charging Stages | Bulk,Absorpotion,FloatBulk,Absorption,Float | ||||
| Temperature Compensation Coefficient | -5mV/℃/Cell/(25℃ref) | ||||
| Temperature Compensation Range | 0℃ to 50℃ | ||||
| Temperature Compensation Set Points | Absoption, Float Absoption, Float | ||||
| Charging Set Points | Absoption Stage, Float Stage | ||||
| Flooded Battery | 14.6V/29.2V/58.4V | ||||
| ARG/Gel Battery(Default) | 14.1V/28.2V/56.4V | ||||
| Overcharge voltage | 15V/30V/60V | ||||
| Overcharge restart voltage | 14.5V/29V/58V | ||||
| Battery discharge voltage | 8.5V/17V/34V | ||||
| Battery overdischarge voltage | 9V/18V/36V | ||||
| Mechanical & Environment | |||||
| Size(H*W*D) | 283*160*105mm | 283*160*105 | 333*215*120mm | ||
| Weight | 4.0KG | 5.1KG | 7.0KG | ||
| Ambient Temperature Range | 0℃ to 50℃ | ||||
| Storage Temperature Range | -40℃ to 75℃ | ||||
| Humidity | 0%-90%RH(No condensing) | ||||
| Enclosure | IP31(indoor&vented) | ||||
Product overview

1. LCD display
2. Power On/Charging indicator
3. Fault and warning indicator
4. Wiring fault indicator
5. Operation button
6. PV Positive +
7. PV Negative -
8. Battery Negative -
9. Battery Positive +
10. Battery voltage sense terminal
11. Remote temperature sensor terminal
12. Communication Port
Login Or Registerto submit your questions to seller
No none asked to seller yet