Must Hybrid Inverter ERROR CODES and Error Codes Meanings by Kreatives

Must Hybrid Inverter ERROR CODES and Error Codes Meanings by Kreatives

Solar Energy & Systems

MUST INVERTER ERROR CODES AND MEANING 

ERROR CODECODE MEANING
01Fan is locked when inverter is off
02Inverter transformer over temperature
03Battery voltage is too high
04Battery voltage is too low
05Output short circuited
06Inverter output voltage is high
07Overload time out
08Inverter bus voltage is too high
09Bus soft start failed
11Main relay failed
21Inverter output voltage sensor error
22Inverter grid voltage sensor error
23Inverter output current sensor error
24Inverter grid current sensor error
25Inverter load current sensor error
26Inverter grid over current error
27Inverter radiator over temperature
31Solar charger battery voltage class error
32Solar charger current sensor error
33Solar charger current is uncontrollable
41Inverter grid voltage is low
42Inverter grid voltage is high
43Inverter grid under frequency
44Inverter grid over frequency
51Inverter over current protection error
52Inverter bus voltage is too low
53Inverter soft start failed
55Over DC voltage in AC output
56Battery connection is open
57Inverter control current sensor error
58Inverter output voltage is too low